MHSC DFX32C Instrucciones de operaciones

Busca en linea o descarga Instrucciones de operaciones para Chimeneas MHSC DFX32C. MHSC DFX32C Operating instructions [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
VENT-FREE FIREPLACE SYSTEMS
INSTALLATION AND OPERATING INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
MODELS
24VFSC
24DBXC*
32VFSC**
Natural Gas or
Propane/LPG
Manual or Milli-Volt
*Thermostat Control Only
•• Milli-Volt Only
This is an unvented gas-red heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate
combustion and ventilation air must be
provided. See page 9.
WARNINGS
If the information in this manual is not followed
exactly, a re or explosion may result causing
property damage, personal injury or loss of
life.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Vista de pagina 0
1 2 3 4 5 6 ... 43 44

Indice de contenidos

Pagina 1 - VENT-FREE FIREPLACE SYSTEMS

VENT-FREE FIREPLACE SYSTEMSINSTALLATION AND OPERATING INSTRUCTIONSREAD AND SAVE THESE INSTRUCTIONSMODELS24VFSC24DBXC*32VFSC**Natural Gas orPropane/LPG

Pagina 2 - CONTENTS

10 33D4051GENERAL INSTALLATION INFORMATIONFigure 3 - Sample Room for Determining the Maximum Heater RatingWARNINGIf the area in which the heater

Pagina 3 - IMPORTANT SAFETY INFORMATION

33D4051 11 GENERAL INSTALLATION INFORMATIONINSTALLING OPTIONAL FIREBRICK PANELS1. Removeoptionalrebrickpanelsfrompackaging.ChecktoSeethat

Pagina 4

12 33D4051GENERAL INSTALLATION INFORMATIONBLACK TRIM INSTALLATION (24VFSC/24DBXC)1. Remove black trim from protective packaging. Remove four

Pagina 5 - PRODUCT FEATURES

33D4051 13 GENERAL INSTALLATION INFORMATION45°-angled Corners Back of Trim Assembly Top Trim Piece Side Trim Pieces 90°-angled Shim90°-angled Bracket

Pagina 6 - PROPANE / LPG

14 33D4051REMOVING SCREEN1. Remove bottom louver. See Figure 14. 2. Removingreplacescreenframepanelbypushingscreenframepanelupandout.

Pagina 7 - 33D4051 7

33D4051 15 GENERAL INSTALLATION INFORMATIONSECURING HEATER TO FLOOR OR HEARTHNote: Clearance requirements as detailed in “CLEARANCES and HEIGHT REQUI

Pagina 8 - 24VFSC/24DBXC 32VFSC

16 33D4051LOCATION OF FIREPLACECarefullyselectthebestlocationforinstallation ofyourunventedreplace.The followingfactorsshouldbetaken

Pagina 9 - 33D4051 9

33D4051 17 9" Minimum42"Minimum9"Minimum12"2 1/2"10"19"CLEARANCES and HEIGHT REQUIREMENTSFigure 20 - Minimum Mant

Pagina 10 - 10 33D4051

18 33D4051HGDFEACCGA1/2" or 5/8"BA1/2" or5/8"CAG 24VFSC 24DBXC 32VFSCA 243/4 243/4 321/2B 263/4 263/4 301/4C 14 14 213/4D 101/2

Pagina 11 - 33D4051 11

33D4051 19 HJNail SidesThrough NailingFlanges 1. Bendoutthenailingangeslocatedoneachsideoftherebox. 2. Slidethereboxintoprepare

Pagina 12 - 12 33D4051

2 33D4051CONTENTSImportant Safety Information ...3Product Features ...

Pagina 13 - 33D4051 13

20 33D4051Pipe CouplingTo Heater Valve3"MinimumCAUTIONCONNECTING THE GASNOTICE: A qualied gas appliance installer must connect the heater to th

Pagina 14 - INSTALLING CANOPY

33D4051 21 WARNINGTest Port “A”CHECKING GAS PRESSURETestallgasjointsfromthegasmetertotheheatervalveforleaksusingagasanalyzerorsoap

Pagina 15 - 33D4051 15

22 33D4051ELECTRICAL WIRING (MILLI-VOLT)The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC T

Pagina 16 - LOCATION OF FIREPLACE

33D4051 23 SKYTECHOFFONREMOTEFIREPLACEREMOTERemote ReceiverVelcro PadVelcro® PadELECTRICAL WIRING (MILLI-VOLT)CONNECTING REMOTE RECEIVERTHESE INSTRUC

Pagina 17 - 19"

24 33D4051LOG PLACEMENTBefore you begin —Thisunitissuppliedwithasetofthreeceramicberlogs.Donothandletheselogswithyourbarehands.

Pagina 18 - /8"

33D4051 25 LOG PLACEMENTPROPER INSTALLATION SEQUENCE (24DBXC) Installone-piecelogontwoburnerpins.See Figure 35. Figure 35 - Proper Sequence of

Pagina 19 - FIREPLACE FRAMING

26 33D4051FLAME APPEARANCEFlames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. Inaddition,pe

Pagina 20 - CONNECTING THE GAS

33D4051 27 INSTALLING ROCK WOOL AND CHECKING BURNER FLAMEPLACING ROCK WOOL24VFSC AND 32VFSC MODELSAfterinstallinglogs,pullapartdime-sizepieces

Pagina 21 - CHECKING GAS PRESSURE

28 33D4051OPERATING INSTRUCTIONSAvoid any drafts that alter burner ame patterns. Donotallowfanstoblowdirectlyintothereplace.Donotplace

Pagina 22 - 22 33D4051

33D4051 29 Figure 44 - Location of Piezo Ignitor & Control KnobPiezoIgnitor FOR YOUR SAFETY READ BEFORE LIGHTING A. Thisapplianceisequippedw

Pagina 23 - Do not place

33D4051 3 9. This unit complies with ANSI Z21.11.2 unvented heaters standard.10. Do not install the VFS Model in a bathroom or bedroom. The DBX Mod

Pagina 24 - LOG PLACEMENT

30 33D4051OPERATING INSTRUCTIONS MANUAL CONTROL LIGHTING INSTRUCTIONS WARNINGWait 30 seconds before readjusting the heater when the control knob has

Pagina 25

33D4051 31 THERMOSTATIC CONTROL LIGHTING INSTRUCTIONS 1. STOP! Read the safety information .2. Make sure the manual shutoff valve is fully open.

Pagina 26 - FLAME APPEARANCE

32 33D4051OPERATING INSTRUCTIONS MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual sh

Pagina 27 - 33D4051 27

33D4051 33 OPERATING INSTRUCTIONS MATCH LIGHTING INSTRUCTIONS  1. Removeanyitemsnecessaryforeasyaccesstothepilot(forexample:logs,scree

Pagina 28 - CHECKING THE BURNER FLAME

34 33D4051CAUTIONBLOWER AND OTHER OPTIONAL EQUIPMENTOPTIONAL EQUIPMENTFORCED AIR KITIfyouareinstallingtheforcedairkit(ModelsBLO24-T,BLO24-T

Pagina 29 - OPERATING INSTRUCTIONS

33D4051 35 143256ILLUSTRATED PARTS BREAKDOWN FOR CABINET ACCESSORIES STANDARD FEATURESITEM DESCRIPTION QTY 24VFSC 24DBXC 32VFSC1 Canopy 1 33D4000 33

Pagina 30

36 33D4051132141510101097816131113125546ILLUSTRATED PARTS BREAKDOWN 24VFSC MILLI-VOLT24VFSC MANUALWARNINGFailure to position the parts in accord

Pagina 31

33D4051 37 REPLACEMENT PARTS LIST REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER. ITEM DESCRIPTION QTY24VFSC MILLIVOLT 24VFSC MANUALNATURAL P

Pagina 32

38 33D4051132991078410411561213141516ILLUSTRATED PARTS BREAKDOWN 32VFSC MILLI-VOLTWARNINGFailure to position the parts in accordance with thes

Pagina 33

33D4051 39 REPLACEMENT PARTS LIST REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER. ITEM DESCRIPTION QTY32VFSC MILLIVOLTNATURAL PROPANE1 Burner

Pagina 34 - OPTIONAL EQUIPMENT

4 33D4051IMPORTANT SAFETY INFORMATIONThis appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not

Pagina 35 - STANDARD FEATURES

40 33D405112108349756ILLUSTRATED PARTS BREAKDOWN 24DBXC T-STAT WARNINGFailure to position the parts in accordance with these diagrams or fai

Pagina 36 - 36 33D4051

33D4051 41 REPLACEMENT PARTS LIST REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER. 24DBXC T-STATITEM DESCRIPTION QTY NATURAL PROPANE1 Burner

Pagina 37 - REPLACEMENT PARTS LIST

42 33D4051TROUBLESHOOTINGIf the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backre when lit. If

Pagina 38 - 38 33D4051

33D4051 43 LIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTYThe following components are warranted for life to the original owner, subject to proo

Pagina 39

August 200833D4051 • Rev. 2MHSC149 Cleveland Drive • Paris, Kentucky 40361www.mhsc.com

Pagina 40 - ILLUSTRATED PARTS BREAKDOWN

33D4051 5 PiezoIgnitionFireplace ScreenControlKnobPRODUCT FEATURESYourvent-freereplacemustbemountedontheoororontheoptionalreplacehea

Pagina 41

6 33D4051NATURAL GAS Manual and T-Stat PressureRegulator Pressure Setting 4 in. w.c.Gas Inlet Pressure: Max. 10.5 in. w.c.Min. 5 in. w.c.PRODUCT F

Pagina 42 - TROUBLESHOOTING

33D4051 7 PILOTThegaslogheateristtedwithaspeciallydesignedsafetypilotlightwhichsensestheamountofoxygenavailableintheroomands

Pagina 43 - 33D4051 43

8 33D4051Inplanningtheinstallationforthereplaceitisnecessarytodeterminewheretheunitistobeinstalledandwhetheroptionalaccessorie

Pagina 44 - 33D4051 • Rev. 2

33D4051 9 GENERAL INSTALLATION INFORMATIONADEQUATE COMBUSTION AND VENTILATION AIRThisheater shallnotbe installedin aconned spaceor unusua

Comentarios a estos manuales