CRLDV/CLLDV FRAMING
INSTALLATION INFORMATION
20306750
9
Designer Series Direct Vent Gas Fireplace
27¹⁄₂” (699 mm)
(1/2” Drywall)
or
27³⁄₈” (696 mm)
(5/8” Drywall)
46¹⁄₈” (1172 mm)
(1/2” Drywall)
or
46” (1168 mm)
(5/8” Drywall)
27⁷⁄₈” (708 mm)
46⁵⁄₈” (1184 mm)
48³⁄₁₆
"
(1224 mm)
FP2849
corner framing
8¹¹⁄₁₆”
(221 mm) Min,
7”
(178 mm)
Min.
4¹⁄₂”
(114 mm)
Min.
Remove box and
Insulation for Top
Vent Congurations
Noncombustible
Material
Fold Outer Tabs
and Nail to Framing
Members
Figure 6 -
CRLDV and CLLDV (Corner) Framing
If using 5/8" drywall, remove
framing tabs and re-install
on 2nd set of holes
positioned slightly inwards
If using 5/8" drywall,
remove framing
tabs and re-install
on 2nd set of holes
positioned slightly
inwards
The replace must be secured to the oor and/or to framing
studs as shown in Figure 6 . Use four (4) wood screws or
masonry/ concrete screws to secure replace to the oor.
Use four (4) screws to attach replace to framing. The side
brackets or nailing anges are designed to accommodate
two wall boards thicknesses, 1/2" or 5/8".
NOTE
Never install combustible materials over
front face of replace.
NOTE
The area above and on the sides of the
replace must be a noncombustible material.
Figures 5, 6, 7
If using 5/8" drywall, remove
noncombustible supports, rotate
180° and reinstall to achieve
5/8" depth